Buscar ubicaciones
Para conocer los horarios, visitas sin turno y citas.No se pudo cargar la navegación global.
Buscar ubicaciones
Para conocer los horarios, visitas sin turno y citas.2 - 4 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
For more information, please view the literature below.
LABupdate: Candida Species Identification by NAA
Microbiology Specimen Collection and Transport Guide
NuSwab℠: Smart Testing Has Arrived
The Most Accurate Results Come From the Best Specimens
Trichomonas vaginalis: Detect More Infections With Nucleic Acid Amplification
Vaginal, endocervical, or male urethral swab, first-void urine (patient should not have urinated for one hour prior to specimen collection), or cervical cells in liquid cytology vial.
One swab, 2 mL of a 20 mL to 30 mL urine collection, or entire liquid cytology vial
One swab, 2 mL of a 20 mL to 30 mL urine collection, or entire liquid cytology vial
Gen-Probe® Aptima® swab or Aptima® urine specimen transport; ThinPrep® liquid cytology vial
Vaginal swab: Care provider specimen: Collect vaginal fluid sample using the Gen-Probe® Aptima® vaginal swab kit by contacting the swab to the lower third of the vaginal wall and rotating the swab for 10 to 30 seconds to absorb fluid. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap. Patient self-collection: Partially open the package of the Gen-Probe® Aptima® vaginal swab kit. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima® swab specimen collection kit. Remove the swab. Carefully insert the swab into the vagina about 2" past the introitus and gently rotate the swab for 10 to 30 seconds, making sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. Withdraw the swab without touching the skin. Immediately place the swab into the transport tube and carefully break the swab shaft against the side of the tube. Tightly screw on the cap.
Endocervical swab: Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white shaft swab in the package with red printing). Discard this swab. Insert the specimen collection swab (blue shaft swab in the package with green printing) into the endocervical canal. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. Withdraw the swab carefully; avoid contact with the vaginal mucosa. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of the contents. Recap the swab specimen transport tube tightly.
Male urethral swab: The patient should not have urinated for at least one hour prior to specimen collection. Insert the specimen collection swab (blue shaft swab in the package with the green printing) 2 to 4 cm into the urethra. Gently rotate the swab clockwise for two to three seconds in the urethra to ensure adequate sampling. Withdraw the swab carefully. Remove the cap from the swab specimen transport tube and immediately place the specimen collection swab into the specimen transport tube. Carefully break the swab shaft at the scoreline; use care to avoid splashing of contents. Recap the swab specimen transport tube tightly.
Urine specimen: The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 mL to 30 mL of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® COMBO 2 urine collection device. The final volume must be between the two black lines on the device (about 2 mL).
Room temperature
Specimen with incorrect patient identification; unlabeled specimen; inappropriate specimen transport conditions; specimens received after prolonged delay (usually >72 hours); specimen leaked in transit; specimen in expired transport or incorrect transport device; specimens with inappropriate source for test requested; specimen with fixative or additives; Aptima® urine transport >30 days from collection; Aptima® urine transport with incorrect specimen volume; <15 mL urine submitted in sterile container; receipt of urine in sterile container >24 hours from collection; Aptima® swab transport >60 days from collection; Aptima® swab specimens with incorrect specimen volume; Aptima® swab specimen without a swab; cleaning swab (white-shaft swab) in Aptima® swab transport; any non−Gen-Probe® swab submitted in Aptima® transport device; wooden-shaft swab in transport device; transport device with multiple swabs; female urethral swab; bloody or grossly mucoid specimens; bacterial swabs; specimen in ProbeTec™ UPT transport; ProbeTec™ Q-swabs; UTM-RT; SurePath™ vial
Diagnosis of Trichomonas vaginalis infection
Nucleic acid amplification (NAA)
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
188052 | Trich vag by NAA | 46154-1 | 188053 | Trich vag by NAA | 46154-1 | |
188052 | Trich vag by NAA | 46154-1 | 019054 | N/A |
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf