Buscar ubicaciones
Para conocer los horarios, visitas sin turno y citas.No se pudo cargar la navegación global.
Buscar ubicaciones
Para conocer los horarios, visitas sin turno y citas.2 - 5 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
Lung biopsy, lung exudate, pleural fluid, transtracheal aspirate, sputum, bronchial washing
1 mL lung exudate or 1 cc lung biopsy
Sterile leakproof container or slides
Contamination with normal flora from skin or other body surfaces should be avoided.
Refrigerate. Maintain specimen at 2°C to 8°C, and transport to the laboratory within 24 hours of collection.
Swab specimen; inappropriate specimen transport device; improper labeling; specimen received after prolonged delay (usually more than 72 hours); environmental water samples such as air conditioning/cooling towers
Determine the presence of Legionella pneumophila organisms in direct FA smear of specimen, providing rapid diagnosis
Test does not include Legionella species other than L pneumophila.
Direct fluorescent antibody (DFA)
No Legionella pneumophila detected
Community-acquired and nosocomial infections caused by multiple serogroups of Legionella are increasingly recognized. Although culture is now possible on buffered charcoal yeast extract agar, the demonstration of organisms in tissue or brushings is the fastest way to make the diagnosis. It also has the advantage of applicability to specimens contaminated with other bacteria. Development of monoclonal antibodies have increased sensitivity and specificity. False-positive reaction has been reported in a case of pleuropulmonary tularemia and in cases of Campylobacter infection.
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
085506 | Legionella pneumophila DFA | 89594-6 | 085506 | Legionella pneumophila DFA | 89594-6 |
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf