Buscar ubicaciones
Para conocer los horarios, visitas sin turno y citas.No se pudo cargar la navegación global.
Buscar ubicaciones
Para conocer los horarios, visitas sin turno y citas.Adalimumab concentration; antiadalimumab antibody level; serial monitoring
6 - 10 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
For more information, please view the literature below.
Inflammatory Bowel Disease Biologics Flyer
Therapeutic Drug Monitoring Options for Rheumatoid Arthritis Flyer
Rheumatic Diseases Biologics (DoseASSURE™) Flyer
Biologic Therapeutic Drug Monitoring Q&A
Serum
2 mL
1 mL (Note: This volume does not allow for repeat testing.)
Red-top tube or gel-barrier tube
Allow a minimum clotting time of 30 to 60 minutes with serum separation within 2 hours of collection. Send serum in a plastic transport tube. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Refrigerate or freeze.
Temperature | Period |
---|---|
Room temperature | 7 days |
Refrigerated | 7 days |
Frozen | 308 days |
Freeze/thaw Cycle | Stable x6 |
Plasma specimen received
Monitor antiadalimumab therapy for individuals with Crohn's disease, inflammatory bowel disease, ulcerative colitis, rheumatoid arthritis, or other autoimmune conditions. This test provides adalimumab drug concentration levels as well as the level of antiadalimumab antibodies.
Electrochemiluminescence immunoassay (ECLIA)
• Adalimumab drug level:
− Quantitation limit: <0.6 μg/mL
− Results ≥0.6 μg/mL indicate detection of adalimumab.
In the presence of antiadalimumab antibody, the adalimumab drug level reflects the antibody-unbound fraction of adalimumab concentration in serum.
• Antiadalimumab antibody:
− Quantitation limit: <25 ng/mL
− Results ≥25 ng/mL indicate detection of adalimumab antibody.
In the absence of antiadalimumab antibodies, the adalimumab drug level typically reflects the total adalimumab concentration in serum. In the presence of antiadalimumab antibodies, the adalimumab level typically reflects the antibody-unbound fraction of adalimumab concentration in serum.
This assay provides clinically valid antibody results at drug levels well above treatment targets (>30 μg/mL). Failure of adalimumab therapy may not always be due to the presence of antiadalimumab antibodies. In addition, the absence of antiadalimumab antibodies does not guarantee positive response to treatment.
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
503890 | Adalimumab Drug + Antibody | 99781-7 | 503866 | Adalimumab Drug Level | ug/mL | 74117-3 |
503890 | Adalimumab Drug + Antibody | 99781-7 | 503867 | Anti-Adalimumab Antibody | ng/mL | 74116-5 |
Reflex Table for Anti-Adalimumab Antibody | ||||||
---|---|---|---|---|---|---|
Order Code | Order Name | Result Code | Result Name | UofM | Result LOINC | |
Reflex 1 | 504107 | Serial Monitoring | 000000 | Serial Monitoring | N/A |
Reflex Table for Anti-Adalimumab Antibody | ||||||
---|---|---|---|---|---|---|
Order Code | Order Name | Result Code | Result Name | UofM | Result LOINC | |
Reflex 1 | 504107 | Serial Monitoring | 511958 | 80563-0 |
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf